پیام فرستادن
خانه محصولاتواحدهای تصفیه هوا

Horizontal Package Fresh Air Handling Unit 4/6 Rows Cooling Coil

Horizontal Package Fresh Air Handling Unit 4/6 Rows Cooling Coil

  • Horizontal Package Fresh Air Handling Unit 4/6 Rows Cooling Coil
  • Horizontal Package Fresh Air Handling Unit 4/6 Rows Cooling Coil
  • Horizontal Package Fresh Air Handling Unit 4/6 Rows Cooling Coil
  • Horizontal Package Fresh Air Handling Unit 4/6 Rows Cooling Coil
Horizontal Package Fresh Air Handling Unit 4/6 Rows Cooling Coil
جزئیات محصول:
Place of Origin: China
نام تجاری: EuroKlimat
گواهی: ISO9001, ISO14001, OHSAS18001, CRAA, CQC
Model Number: EKSW-H
پرداخت:
Minimum Order Quantity: 1
قیمت: negotiation
Packaging Details: Plywood
Delivery Time: 15 working days after received your payment
Payment Terms: L/C, T/T
Supply Ability: 5,000pcs per month
مخاطب
توضیحات محصول جزئیات
Product Name: Fresh Air Handling Unit Installation: Ceiling hang/floor installation
Cooling Capacity(kW): 12-258.9 Heating Capacity(kW): 18.5-287.2
Air Flow(m3/h): 2000-15000 Aluminum Fins: Shutter-type hyperbolic and hydrophilic fins
Test Pressure (Mpa): 3.3 Coils rows: 4/6
برجسته:

custom air handling units,hvac air handling unit

,

hvac air handling unit

EK keeps looking for valuable distributors and partners around international markets…

 

Horizontal Package Fresh Air Handling Unit 4/6 rows cooling Coil

 

Specifications

 

Unit Model EKSW
020H
EKSW
030H
EKSW
040H
EKSW
050H
EKSW
060H
EKSW
070H
EKSW
080H
EKSW
090H
EKSW
100H
EKSW
120H 
EKSW
135H
EKSW
150H
Nominal air flow (m3/h) 2000 3000 4000 5000 6000 7000 8000 9000 10000 12000 13500 15000
External total pressure (Pa) I 80 80 80 80 80 80 80 80 - - - -
II 150 150 150 150 150 150 150 150 150 150 150 150
III 220 220 220 220 220 220 220 220 220 220 220 220
IV 300 300 300 300 300 300 300 300 300 300 300 300
Nominal cooling capacity (kW) Four rows of coils (in air return condition) 12.0  18.8  25.9  31.9  36.9  43.9  50.0  55.4  61.6  76.2  80.6  90.9 
Four rows of coils (in fresh air condition)  28.7 40.8  56.1  72.0  85.2  97.3  110.0  125.4  139.3  164.8  174.8  200.1 
Six rows of coils (in air return condition)  15.9  23.7  32.7  40.1  49.8  55.8  63.5  72.4  78.0  94.7  107.9  115.5 
Six rows of coils (in fresh air condition) 35.5  54.4  70.0  90.5  109.9  126.9  136.6  155.4  176.6  211.9  235.8  258.9 
Nominal heating capacity (kW) Four rows of coils (in air return condition) 18.5  28.8  38.8  47.9  56.9  67.1  81.3  91.5  101.6  122.0  135.7  150.7 
Four rows of coils (in fresh air condition)  30.6 44.8  60.5  76.4  92.8  109.4  127.9  145.5  161.6  194.0  211.2  237.2 
Six rows of coils (in air return condition)  23.0  34.3  46.4  57.7  69.9  80.7  96.4  109.0  119.9  144.0  162.7  178.1 
Six rows of coils (in fresh air condition) 36.4  54.9  72.4  91.4  110.7  129.2  150.3  170.0  189.8  227.8  257.4  287.2 
Nominal cold water flow (L/S) Four rows of coils (in air return condition) 0.57  0.89  1.24  1.52  1.76  2.09  2.38  2.64  2.94  3.63  3.84  4.33 
Four rows of coils (in fresh air condition)  1.36  1.94  2.67  3.43  4.06  4.64  5.24  5.97  6.63  7.85  8.32  9.53 
Six rows of coils (in air return condition)  0.76  1.13  1.56  1.91  2.37  2.66  3.03  3.45  3.71  4.51  5.14  5.50 
Six rows of coils (in fresh air condition) 1.69  2.59  3.34  4.31  5.24  6.04  6.50  7.40  8.41  10.09  11.23  12.33 
Nominal hot water flow (L/S) Four rows of coils (in air return condition) 0.44  0.69  0.92  1.14  1.35  1.60  1.94  2.18  2.42  2.90  3.23  3.59 
Four rows of coils (in fresh air condition)  0.73  1.07  1.45  1.82  2.21  2.61  3.05  3.46  3.85  4.62  5.03  5.65 
Six rows of coils (in air return condition)  0.55  0.82  1.10  1.37  1.66  1.92  2.30  2.59  2.85  3.43  3.87  4.24 
Six rows of coils (in fresh air condition) 0.87  1.31  1.72  2.18  2.64  3.08  3.58  4.05  4.52  5.42  6.13  6.84 
Fins/inch Model High-quality air conditioner copper tubes are connected to 
hyperbolic aluminum plate-fins through mechanical expanding.
Heat exchanger 12
Working pressure (MPa)  1.6
Inlet/outlet pipe connector size R1-1/2 R1-1/2 R1-1/2 R2 R2 R2 R2 R2 R2 R2-1/2 R2-1/2 R2-1/2
Condensed water pipe connector size R1-1/4
Fan Type/material Efficient centrifugal forward curved fan/galvanized steel plate
Transmission mode Efficient V-belt transmission
Air supply direction of the fan Downward horizontal
Motor  Power supply  380V/3~/50H
Model Tri-phase asynchronous motor, F-rate insulation, and IP54 protection
Rated power
of motor (kW)
I

0.37

(0.37)

0.55

(0.55)

0.55

(0.75)

1.1

(1.1)

1.1

(1.1)

1.1

(1.5)

1.1

(1.1)

1.1

(1.5)

- - - -
II

0.37

(0.55)

0.55

(0.55)

0.75

(0.75)

1.1

(1.1)

1.1

(1.5)

1.5

(1.5)

1.1

(1.5)

1.5

(1.5)

2.2

(2.2)

2.2

(2.2)

2.2

(3.0)

3.0

(3.0)

III

0.55

(0.55)

0.55

(0.75)

0.75

(1.1)

1.1

(1.5)

1.5

(1.5)

1.5

(2.2)

1.5

(2.2)

1.5

(2.2)

2.2

(2.2)

2.2

(3.0)

3.0

(3.0)

3.0

(3.0)

IV

0.55

(0.55)

0.75

(0.75)

1.1

(1.1)

1.5

(1.5)

1.5

(2.2)

2.2

(2.2)

2.2

(2.2)

2.2

(2.2)

2.2

(3.0)

3.0

(3.0)

3.0

(3.0)

3.0

(4.0)

Unit noise (dB(A)) I 52 55 57 59 60 62 62 62 - - - -
II 53 56 58 60 61 63 63 63 63 62 63 65
III 54 57 59 61 62 64 64 64 64 63 64 66
IV 55 58 60 62 63 65 65 65 65 64 65 67
Filter Model Primary nylon filter (connected through 8 mm hook)
Box  Model The galvanized steel plate applies static spraying and the internal is 
attached with efficient insulation sound-proof PE material.
Unit Outer Dimensions Length (mm) 1090 1090 1181 1381 1581 1781 1671 1771 1921 2037 2237 2447
Width (mm)  831 1051 1090 1090 1090 1090 1185 1185 1185 1235 1235 1235
Height (mm)  505 505 570 570 570 570 670 670 670 742 742 742
Unit weight (kg) Four rows of coils  79 98 118 130 152 163 194 198 217 262 287 300
Six rows of coils  82 102 124 136 160 172 207 212 232 280 307 322

Note:
■ The preceding parameters apply to the standard model. EK provides customized design to meet special requirements.
■ Nominal air return cooling condition: 27°C (dry bulb)/19.5°C (wet bulb). Nominal fresh air cooling condition: 34°C (dry bulb)/28°C (wet bulb). Nominal cooling water inlet/outlet temperature: inlet
7°C; outlet 12°C.
■ Nominal air return heating condition: 21°C (dry bulb). Nominal fresh air heating condition: 0°C (dry bulb). Nominal heating water inlet/outlet temperature: inlet 60°C; outlet 50°C.
■ The unit weight listed in the table is net weight. The operating weight increases by about 20%.
■ The value in brackets in the table indicates the motor power for a unit with 6 rows of coils.
■ The noise values in the preceding table are measured at a distance of 1 m from the unit in a state certified standard semi-anechoic room according to the GBT 9068-1988 standard.
■ If the external total pressure value of the unit used in model selection is large, the air flow will be large, leading to noise and water spray. Therefore, carefully determine the air duct resistance.
■ The coil loop form varies from a full air-return unit to a full fresh air unit. Mark the air inlet condition at purchase. Specify R for a full air-return unit and F for a full fresh air unit. EK provides model
selection software for special requirements. For specific parameters, see the model selection result.

 

Design

 

Complete design parameters of the standard unit such as water flow and water pressure drop
Comprehensive secondary design software
Comprehensive non-standard design flow and wide application scope
The proprietary integrated computer-based model selection software is specifically designed
for EKSW units for model selection and matching. This software can flexibly and conveniently
select proper units according to customer requirements and provide specific model selection
results for customers.

Purifying and sterilizing device (optional)

 

Aluminum filter

 

■ It can filter out large granular dust such as lampblack.
■ The aluminum frame structure reduces the maintenance cost.
■ The precise aluminum mesh structure is easy to install and clean.Electric purifier
■ Using high-voltage static cleaning technology, it effectively eliminates dust, germs,virus, and harmful gases.
■ It provides multiple layers of protection by using multiple levels of filtering.
■ The modular combination design helps determine reasonable configuration according to the air flow.

Photo catalyst ultraviolet lamp for sterilization

■ It effectively prevents germs and moulds on coils and eliminates smells that are thereby generated.
■ The photo catalyst does not suffer change or loss, and lasts long.
■ It can effectively decompose pollutants such as methanol, methylbenzene, and ammonia. It is not toxic or harmful, and does not produce pollution.

 

Wet-film humidifier

 

Clean running water that passes through the electromagnetic valve is sent to a water distributor at the top of the wet film over a water pipe. The water flows downwardly at the surface of the wet film under gravity to wet the surface of the wet film. The water that arrives at the water tray is discharged to the drainage pipe through a bent water drainage pipe. That is, the water is not recycled. When hot air passes through the humid wet film, its humidity increases and its temperature drops. This humidification
process is called isoenthalpic humidification process. During this process, certain water on the wet film is evaporated, which does not consume extra energy. The working principle of wet-film direct
drainage humidifier is shown in the figure on the right.

اطلاعات تماس
Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd

تماس با شخص: Mr. LENG Zhengliang

تلفن: +86 13828797702

فکس: 86-0769-83622528

ارسال درخواست خود را به طور مستقیم به ما (0 / 3000)

سایر محصولات